GasAlert Extreme
User Manual
Automatic Shutdown Alarm
There are two situations when an automatic shutdown alarm
occurs:
1. If the battery voltage is in immediate danger of
dropping below the minimum operating voltage, the
audible alarm beeps eight times, the visual alarm
flashes eight times, and the detector emits eight
vibrations. After 3 seconds, the LCD powers off and
the detector stops normal operation. The LCD
periodically displays the low battery icon
until the
battery power is depleted.
For directions about how to replace the battery,
refer to
Replacing the Battery or Sensor.
Note
The low battery alarm continues for approximately
30 minutes before an automatic shutdown occurs.
2. If the calibration past protection user option is
active and the detector is past the calibration due
date, the detector performs an automatic shutdown.
Calibration and Setting Alarm Setpoints
Guidelines
When calibrating the detector, adhere to the following
guidelines.
Recommended gas mixture:
O
2
: clean air, 20.9% vol.
CO (low H
2
sensitivity): 50 to 500 ppm balance N
2
CO: 50 to 500 ppm balance N
2
H
2
S (high range): 10 to 100 ppm balance N
2
H
2
S (low methanol): 10 to 100 ppm balance N
2
H
2
S: 10 to 100 ppm balance N
2
PH
3
: 1 to 5 ppm balance N
2
SO
2
: 10 to 50 ppm balance N
2
Cl
2
: 3 to 25 ppm balance N
2
NH
3
: 20 to 100 ppm balance N
2
NH
3
: (high range) 20 to 100 ppm balance N
2
NO
2
: 5 to 50 ppm balance N
2
HCN: 5 to 20 ppm balance N
2
ETO: 5 to 50 ppm balance N
2
ClO
2
: 0.1 to 1.0 ppm balance N
2
O
3
: 0.1 to 1.0 ppm balance N
2
NO: 10 to 250 ppm balance N
2
For ETO detectors (before each day’s use) allow the
instrument to fully stabilize in the temperature that it is to
be operated in and then zero the detector.