BW Technologies GasAlert Extreme User Manual Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 63
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
GasAlert Extreme
User Manual
38
Setting the STEL Alarm Setpoint
Note
To bypass and retain the current STEL alarm setpoint value,
press
C. The detector automatically proceeds to the low
alarm setpoint.
When the TWA alarm setpoint value has been changed or bypassed, the
Set STEL alarm setpoint screen displays.
14. Press
D or E to scroll to the required value.
15. Press
C to save the new value and proceed to the low alarm
setpoint.
Note
If a new value is selected but not confirmed within 10 seconds
by pressing
C, the detector automatically retains the original
value and NO displays. The detector proceeds to the low alarm
setpoint.
Setting the Low Alarm Setpoint
Note
To bypass and retain the current low alarm setpoint value,
press
C. The detector automatically proceeds to the high
alarm setpoint.
When the STEL alarm setpoint value has been changed or bypassed,
the Set LOW alarm setpoint screen displays.
\
16. Press D or E to scroll to the required value.
17. Press
C to save the new value and proceed to the high alarm
setpoint.
Note
If a new value is selected but not confirmed within 10 seconds
by pressing
C, the detector automatically retains the original
value and NO displays. The detector proceeds to the high
alarm setpoint.