Table 14. Troubleshooting Tips
Problem Possible Cause Solution
The detector does not activate. No battery Install a battery. Refer to Replacing the Bat-
tery or Sensor.
Depleted battery Replace the battery. Refer to Replacing the
Battery or Sensor.
Damaged or defective detector Contact BW Technologies by Honeywell
.
Reversed battery Reinstall the battery correctly.
The detector enters alarm mode immedi-
ately when it is activated.
Sensor needs to stabilize Used sensor: wait 60 seconds.
New sensor: wait 5 minutes.
Low battery alarm Replace the battery. Refer to Replacing the
Battery or Sensor.
Sensor alarm Replace the sensor. Refer to Replacing the
Battery or Sensor.
The start up self-test fails during one of the
checks.
General fault Contact BW Technologies by Honeywell
.
Alarm setpoints are incorrect Reset the alarm setpoints. Refer to Reset-
ting Gas Alarm Setpoints.