GasAlert Extreme
User Manual
17
Disable Passcode Protection
When the detector is passcode protected, the key icon displays continu-
ally. To disable the passcode protection option, complete the following:
1. Press and hold
D and E simultaneously to access the user
options menu.
The OPTN screen displays briefly before the flashing passcode
screen displays.
2. Press
D or E to scroll to the required passcode and press C
to confirm. The following EXIT screen displays.
The key icon indicates that the passcode protection is currently
enabled.
3. Press
D or E to scroll to the PASS option, and press C to
select the option.
4. The LCD displays a flashing OFF screen. Press
C to confirm
the disabling option.
Note
To ensure if the passcode protection option is enabled/dis-
abled, use
D and E to toggle between the ON and OFF
options. Display the desired option and press
C to confirm the
selection.
The LCD returns to the EXIT screen.
5. Press
D or E to select another user option, or press C to exit
the user options and return to normal operation.
Note
If a passcode value is not selected or confirmed by pressing
C within 10 seconds, NO displays and the LCD returns to the
EXIT screen.
Deactivation Passcode Protection
As a backup safety precaution, the deactivation passcode protection
option can be enabled prevent unauthorized deactivation. A separate
security passcode is required for this option and will be available to lim-
ited personnel only.
Note
The detector can be shipped with this option enabled perma-
nently. This option can only be enabled at the factory and can-
not be disabled by a customer.
The passcode must be entered every time the detector is deactivated.