BW Technologies GasAlert Extreme User Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 63
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
GasAlert Extreme
User Manual
35
Passcode Protected
After a successful auto zero, and if the passcode protected option is
enabled, PASS displays. The passcode is required to access the auto
span and alarm setpoint functions.
3. Press
D or E to scroll to the required passcode and press C
to confirm. For additional information, refer to Passcode Protec-
tion Option.
If the correct code is confirmed by pressing
C within 10 sec-
onds, the detector beeps twice and automatically proceeds to the
set span screen.
If the passcode is not confirmed within 10 seconds or the pass-
code is incorrect, NO displays.
The detector then beeps four times and automatically returns to
normal operation.
Set Span
Note
To bypass the set span function, press
C to automatically pro-
ceed to the span screen.
The set span function inputs a new calibration gas concentration value.
4. Set SPAN flashes.
Press
D or E to scroll to the required gas concentration. The
detector value must match the concentration value on the gas
cylinder.
Note
If a new value is selected but not confirmed within 10 seconds
by pressing
C, the detector rejects the new value and NO dis-
plays. The detector beeps six times and retains the original
value. The detector automatically proceeds to the span screen.
5. Press
C to save the new value and proceed to the span screen.
Page view 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 62 63

Comments to this Manuals

No comments